VO-XMvKas Eca

Installationsltg, VPE-isoliert mit Cu-Leitern und konz. Leiter aus Stahl- u. Cu-Drähten und PVC-Mantel

VO-XMvKas Eca

according K42-C-07.

  • Variants
  • Downloads
  • Shorter and longer lengths
  • Number of cores

    Cross section conductor

    Technical features Product
    VO-XMvKas Eca Eca 2x2,5 RE/2,5 2 2.5 mm²
    Conductor material
    Copper
    Nominal cross section conductor
    2.5 mm²
    Conductor Diameter
    2.5 mm
    Conductor category
    Class 1 = solid
    Conductor resistance at 20 °C
    7.41 Ohm/km
    Number of cores
    2
    Core insulation material
    Polyolefin
    Core identification according to HD 308 S2
    Yes
    Core colour
    Protective conductor
    No
    Max. conductor temperature
    90 °C
    Screen
    No
    Armouring/reinforcement
    Braiding
    Material outer sheath
    Polyvinyl chloride (PVC)
    Colour outer sheath
    Grey
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    12 mm
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -20 <=> 70 °C
    Nominal voltage U0
    450 V
    Nominal voltage U
    750 V
    Shape of conductor
    Round
    Suitable as installation cable
    Yes
    Certified for shipboard application
    No
    Suitable as medium-voltage cable
    No
    Suitable as high-voltage cable
    No
    Certified as airport lighting cable
    No
    Weight
    215.37 kg/km
    Minimum bending radius
    12 x Außen-Ø
    max. short circuit temperature
    250 °C
    Product No. Individual length Pallet unit Packing
    560172 Cut length Ring, Drum
    597642 100 m 3,000 Ring
    VO-XMvKas Eca Eca 3X1,5 RE/1,5 3 1.5 mm²
    Conductor material
    Copper
    Nominal cross section conductor
    1.5 mm²
    Conductor Diameter
    1.5 mm
    Conductor category
    Class 1 = solid
    Conductor resistance at 20 °C
    12.1 Ohm/km
    Number of cores
    3
    Core insulation material
    Polyolefin
    Core identification according to HD 308 S2
    Yes
    Core colour
    Protective conductor
    No
    Max. conductor temperature
    90 °C
    Screen
    No
    Armouring/reinforcement
    Braiding
    Material outer sheath
    Polyvinyl chloride (PVC)
    Colour outer sheath
    Grey
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    12 mm
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -20 <=> 70 °C
    Nominal voltage U0
    450 V
    Nominal voltage U
    750 V
    Shape of conductor
    Round
    Suitable as installation cable
    Yes
    Certified for shipboard application
    No
    Suitable as medium-voltage cable
    No
    Suitable as high-voltage cable
    No
    Certified as airport lighting cable
    No
    Weight
    205.86 kg/km
    Minimum bending radius
    12 x Außen-Ø
    max. short circuit temperature
    250 °C
    Product No. Individual length Pallet unit Packing
    585717 Cut length Ring, Drum
    VO-XMvKas Eca Eca 3X2,5 RE/2,5 3 2.5 mm²
    Conductor material
    Copper
    Nominal cross section conductor
    2.5 mm²
    Conductor Diameter
    2.5 mm
    Conductor category
    Class 1 = solid
    Conductor resistance at 20 °C
    7.41 Ohm/km
    Number of cores
    3
    Core insulation material
    Polyolefin
    Core identification according to HD 308 S2
    Yes
    Core colour
    Protective conductor
    No
    Max. conductor temperature
    90 °C
    Screen
    No
    Armouring/reinforcement
    Braiding
    Material outer sheath
    Polyvinyl chloride (PVC)
    Colour outer sheath
    Grey
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    13 mm
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -20 <=> 70 °C
    Nominal voltage U0
    450 V
    Nominal voltage U
    750 V
    Shape of conductor
    Round
    Suitable as installation cable
    Yes
    Certified for shipboard application
    No
    Suitable as medium-voltage cable
    No
    Suitable as high-voltage cable
    No
    Certified as airport lighting cable
    No
    Weight
    243.71 kg/km
    Minimum bending radius
    12 x Außen-Ø
    max. short circuit temperature
    250 °C
    Product No. Individual length Pallet unit Packing
    560202 Cut length Ring, Drum
    590957 100 m 1,600 Ring
    590964 500 m 2,000 Drum
    VO-XMvKas Eca Eca 4X2,5 RE/2,5 4 2.5 mm²
    Conductor material
    Copper
    Nominal cross section conductor
    2.5 mm²
    Conductor Diameter
    2.5 mm
    Conductor category
    Class 1 = solid
    Conductor resistance at 20 °C
    7.41 Ohm/km
    Number of cores
    4
    Core insulation material
    Polyolefin
    Core identification according to HD 308 S2
    Yes
    Core colour
    Protective conductor
    No
    Max. conductor temperature
    90 °C
    Screen
    No
    Armouring/reinforcement
    Braiding
    Material outer sheath
    Polyvinyl chloride (PVC)
    Colour outer sheath
    Grey
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    13 mm
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -20 <=> 70 °C
    Nominal voltage U0
    450 V
    Nominal voltage U
    750 V
    Shape of conductor
    Round
    Suitable as installation cable
    Yes
    Certified for shipboard application
    No
    Suitable as medium-voltage cable
    No
    Suitable as high-voltage cable
    No
    Certified as airport lighting cable
    No
    Weight
    274.3 kg/km
    Minimum bending radius
    12 x Außen-Ø
    max. short circuit temperature
    250 °C
    Product No. Individual length Pallet unit Packing
    560233 Cut length Ring, Drum
    597659 100 m 1,400 Ring
  • Title Language
    Datasheet
    Declaration of Performance
  • We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.

    If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.

    To shorter and longer lengths "VO-XMvKas Eca"