YMvK-ss Dca 1x

Power cable, XLPE insulated, copper conductor, improved behavior in case of fire

YMvK-ss Dca 1x

according HD 604 4D.

  • Variants
  • Downloads
  • Shorter and longer lengths
  • Number of cores

    Cross section conductor

    Technical features Product
    YMvK-ss Dca 1x 1X25 RF 1 25 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    25 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    12 mm
    Weight
    306.73 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    545766 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X35 RF 1 35 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    35 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    13 mm
    Weight
    422.6 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    481866 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X50 RF 1 50 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    50 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    15 mm
    Weight
    586.56 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    481903 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X70 RF 1 70 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    70 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    17 mm
    Weight
    725.69 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    483006 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X95 RF 1 95 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    95 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    19 mm
    Min. permitted bending radius, stationary application/permanent installation
    285 mm
    Weight
    978.39 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    287086 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X120 RF 1 120 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    120 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    21 mm
    Min. permitted bending radius, stationary application/permanent installation
    315 mm
    Weight
    1,219.4 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    287116 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X150 RF 1 150 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    150 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    23 mm
    Min. permitted bending radius, stationary application/permanent installation
    345 mm
    Weight
    1,492 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    287130 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X185 RF 1 185 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    185 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    24 mm
    Weight
    1,844.4 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    287154 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X240 RF 1 240 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    240 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    29 mm
    Min. permitted bending radius, stationary application/permanent installation
    435 mm
    Weight
    2,424.6 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    287178 Cut length Ring, Drum
    YMvK-ss Dca 1x 1X300 RF 1 300 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    300 mm²
    Conductor category
    Class 5 = flexible
    Shape of conductor
    Round
    Number of cores
    1 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Dca
    Reaction-to-fire according to EN 13501-6: Smoke production
    s2
    Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    d2
    Reaction-to-fire according to EN 13501-6: Acidity
    a3
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    31 mm
    Weight
    2,984.8 kg/km
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    287192 Cut length Ring, Drum
  • Title Language
    Datasheet
    Declaration of Performance
  • We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.

    If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.

    To shorter and longer lengths "YMvK-ss Dca 1x"