N2XS2Y 20kV
according VDE 0276 part 620.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product N2XS2Y 20kV 1X35 RM/16 20kV 1 35 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 35 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 29 mm
- Min. permitted bending radius, stationary application/permanent installation
- 435 mm
- Weight
- 902.67 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240821 Cut length Ring, Drum N2XS2Y 20kV 1X50 RM/16 20kV 1 50 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 50 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 30 mm
- Min. permitted bending radius, stationary application/permanent installation
- 450 mm
- Weight
- 1,037.1 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240869 Cut length Ring, Drum N2XS2Y 20kV 1X70 RM/16 20kV 1 70 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 70 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 32 mm
- Min. permitted bending radius, stationary application/permanent installation
- 480 mm
- Weight
- 1,263.8 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240906 Cut length Ring, Drum N2XS2Y 20kV 1X95 RM/16 20kV 1 95 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 95 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 34 mm
- Min. permitted bending radius, stationary application/permanent installation
- 510 mm
- Weight
- 1,534.55 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240920 Cut length Ring, Drum N2XS2Y 20kV 1X120 RM/16 20kV 1 120 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 120 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 35 mm
- Min. permitted bending radius, stationary application/permanent installation
- 525 mm
- Weight
- 1,779.6 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240722 Cut length Ring, Drum N2XS2Y 20kV 1X150 RM/25 20kV 1 150 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 150 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 37 mm
- Min. permitted bending radius, stationary application/permanent installation
- 555 mm
- Weight
- 2,144.84 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240746 Cut length Ring, Drum N2XS2Y 20kV 1X240 RM/25 20kV 1 240 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 240 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 41 mm
- Min. permitted bending radius, stationary application/permanent installation
- 615 mm
- Weight
- 3,054.41 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240784 Cut length Ring, Drum N2XS2Y 20kV 1X300 RM/25 20kV 1 300 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 300 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 43 mm
- Min. permitted bending radius, stationary application/permanent installation
- 645 mm
- Weight
- 3,639.52 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240807 Cut length Ring, Drum N2XS2Y 20kV 1X400 RM/35 20kV 1 400 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 400 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 46 mm
- Min. permitted bending radius, stationary application/permanent installation
- 690 mm
- Weight
- 4,538.9 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 236015 Cut length Ring, Drum 240845 Cut length Ring, Drum N2XS2Y 20kV 1X500 RM/35 20kV 1 500 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 500 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyolefin
- Specification material outer sheath
- Polyethylene (PE)
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- No
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 49 mm
- Min. permitted bending radius, stationary application/permanent installation
- 735 mm
- Weight
- 5,576.4 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -20 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 240883 Cut length Ring, Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "N2XS2Y 20kV"