NYCWY

Power cable, PVC insulated, copper conductor, concentric copper conductor waveform

NYCWY

According to VDE 0276 part 603.

  • Variants
  • Downloads
  • Shorter and longer lengths
  • Number of cores

    Cross section conductor

    Technical features Product
    NYCWY 2X10 RE/10 2 10 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    10 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    2 Stck
    Core identification according to HD 308 S2
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    10 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Cable geometry
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    18 mm
    Min. permitted bending radius, stationary application/permanent installation
    216 mm
    Weight
    588.75 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    Suitable as installation cable
    Certified for shipboard application
    Suitable as medium-voltage cable
    Suitable as high-voltage cable
    Certified as airport lighting cable
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    239405 Cut length Ring, Drum
    NYCWY 2X16 RE/16 2 16 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    16 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    2 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    16 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    20 mm
    Min. permitted bending radius, stationary application/permanent installation
    240 mm
    Weight
    813.89 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    249237 Cut length Ring, Drum
    NYCWY 3X10 RE/10 3 10 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    10 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    10 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    19 mm
    Min. permitted bending radius, stationary application/permanent installation
    228 mm
    Weight
    685.71 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    247615 Cut length Ring, Drum
    247639 500 m 500 Drum
    NYCWY 3X16 RE/16 3 16 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    16 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    16 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    21 mm
    Min. permitted bending radius, stationary application/permanent installation
    252 mm
    Weight
    960.26 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    247653 Cut length Ring, Drum
    247677 500 m 500 Drum
    NYCWY 3X25 RM/16 3 25 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    25 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    16 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    25 mm
    Min. permitted bending radius, stationary application/permanent installation
    300 mm
    Weight
    1,380.5 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    247691 Cut length Ring, Drum
    NYCWY 3X35 RM/16 3 35 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    35 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    16 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    28 mm
    Weight
    1,732.9 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    358342 Cut length Ring, Drum
    NYCWY 3X50 SM/25 3 50 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    50 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    25 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    28 mm
    Min. permitted bending radius, stationary application/permanent installation
    336 mm
    Weight
    2,030.9 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    247806 Cut length Ring, Drum
    NYCWY 3X70 SM/35 3 70 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    70 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    35 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    31 mm
    Min. permitted bending radius, stationary application/permanent installation
    372 mm
    Weight
    2,794.2 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    247875 Cut length Ring, Drum
    NYCWY 3X95 SM/50 3 95 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    95 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    50 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    38 mm
    Min. permitted bending radius, stationary application/permanent installation
    456 mm
    Weight
    4,001.9 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    247943 Cut length Ring, Drum
    NYCWY 3X120 SM/70 3 120 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    120 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    70 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    40 mm
    Min. permitted bending radius, stationary application/permanent installation
    480 mm
    Weight
    4,846.1 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248810 Cut length Ring, Drum
    NYCWY 3X150 SM/70 3 150 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    150 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    70 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    44 mm
    Min. permitted bending radius, stationary application/permanent installation
    528 mm
    Weight
    5,865.7 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248889 Cut length Ring, Drum
    NYCWY 3X185 SM/95 3 185 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    185 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    95 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    49 mm
    Min. permitted bending radius, stationary application/permanent installation
    588 mm
    Weight
    7,490.5 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    247998 Cut length Ring, Drum
    NYCWY 3X240 SM/120 3 240 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    240 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    3 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    120 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    52 mm
    Min. permitted bending radius, stationary application/permanent installation
    624 mm
    Weight
    9,353.2 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248018 Cut length Ring, Drum
    NYCWY 4X10 RE/10 4 10 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    10 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    10 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    20 mm
    Min. permitted bending radius, stationary application/permanent installation
    240 mm
    Weight
    812.38 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248032 Cut length Ring, Drum
    248056 500 m 500 Drum
    NYCWY 4X16 RE/16 4 16 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    16 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    16 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    23 mm
    Min. permitted bending radius, stationary application/permanent installation
    276 mm
    Weight
    1,144.7 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248070 Cut length Ring, Drum
    248094 500 m 500 Drum
    NYCWY 4X25 RM/16 4 25 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    25 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    16 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    27 mm
    Min. permitted bending radius, stationary application/permanent installation
    324 mm
    Weight
    1,672.7 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248117 Cut length Ring, Drum
    248131 500 m 500 Drum
    NYCWY 4X35 RM/16 4 35 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    35 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    16 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    30 mm
    Weight
    2,119.3 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    358304 Cut length Ring, Drum
    732784 500 m 500 Drum
    NYCWY 4X50 SM/25 4 50 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    50 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    25 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    32 mm
    Min. permitted bending radius, stationary application/permanent installation
    384 mm
    Weight
    2,646.3 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248230 Cut length Ring, Drum
    248278 500 m 500 Drum
    NYCWY 4X70 SM/35 4 70 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    70 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    35 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    34 mm
    Min. permitted bending radius, stationary application/permanent installation
    408 mm
    Weight
    3,515.8 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248537 Cut length Ring, Drum
    NYCWY 4X95 SM/50 4 95 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    95 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    50 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    40 mm
    Min. permitted bending radius, stationary application/permanent installation
    480 mm
    Weight
    4,933 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248599 Cut length Ring, Drum
    671021 500 m 500 Drum
    NYCWY 4X120 SM/70 4 120 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    120 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    70 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    45 mm
    Min. permitted bending radius, stationary application/permanent installation
    540 mm
    Weight
    6,241.9 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248674 Cut length Ring, Drum
    670963 500 m 500 Drum
    NYCWY 4X150 SM/70 4 150 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    150 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    70 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    47 mm
    Min. permitted bending radius, stationary application/permanent installation
    564 mm
    Weight
    7,342.1 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248711 Cut length Ring, Drum
    670970 500 m 500 Drum
    NYCWY 4X185 SM/95 4 185 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    185 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4 Stck
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    95 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    54 mm
    Min. permitted bending radius, stationary application/permanent installation
    648 mm
    Weight
    9,382.3 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248766 Cut length Ring, Drum
    670987 500 m 500 Drum
    NYCWY 4X240 SM/120 4 240 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    240 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4 Stck
    Core identification according to HD 308 S2
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    120 mm²
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Black
    Cable geometry
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    59 mm
    Min. permitted bending radius, stationary application/permanent installation
    708 mm
    Weight
    11,919 kg/km
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Permitted cable outer temperature after assembling without vibration
    -30 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    Suitable as installation cable
    Certified for shipboard application
    Suitable as medium-voltage cable
    Suitable as high-voltage cable
    Certified as airport lighting cable
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Product No. Individual length Pallet unit Packing
    248797 Cut length Ring, Drum
    670994 500 m 500 Drum
  • Title Language
    Datasheet
    Declaration of Performance
  • We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.

    If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.

    To shorter and longer lengths "NYCWY"