NYCWY
According to VDE 0276 part 603.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product NYCWY 2X10 RE/10 2 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification according to HD 308 S2
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Cable geometry
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 18 mm
- Min. permitted bending radius, stationary application/permanent installation
- 216 mm
- Weight
- 588.75 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- Suitable as installation cable
- Certified for shipboard application
- Suitable as medium-voltage cable
- Suitable as high-voltage cable
- Certified as airport lighting cable
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 239405 Cut length Ring, Drum NYCWY 2X16 RE/16 2 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 20 mm
- Min. permitted bending radius, stationary application/permanent installation
- 240 mm
- Weight
- 813.89 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 249237 Cut length Ring, Drum NYCWY 3X10 RE/10 3 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 19 mm
- Min. permitted bending radius, stationary application/permanent installation
- 228 mm
- Weight
- 685.71 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247615 Cut length Ring, Drum 247639 500 m 500 Drum NYCWY 3X16 RE/16 3 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 21 mm
- Min. permitted bending radius, stationary application/permanent installation
- 252 mm
- Weight
- 960.26 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247653 Cut length Ring, Drum 247677 500 m 500 Drum NYCWY 3X25 RM/16 3 25 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 25 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 25 mm
- Min. permitted bending radius, stationary application/permanent installation
- 300 mm
- Weight
- 1,380.5 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247691 Cut length Ring, Drum NYCWY 3X35 RM/16 3 35 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 35 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 28 mm
- Weight
- 1,732.9 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 358342 Cut length Ring, Drum NYCWY 3X50 SM/25 3 50 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 50 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 25 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 28 mm
- Min. permitted bending radius, stationary application/permanent installation
- 336 mm
- Weight
- 2,030.9 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247806 Cut length Ring, Drum NYCWY 3X70 SM/35 3 70 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 70 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 35 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 31 mm
- Min. permitted bending radius, stationary application/permanent installation
- 372 mm
- Weight
- 2,794.2 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247875 Cut length Ring, Drum NYCWY 3X95 SM/50 3 95 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 95 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 50 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 38 mm
- Min. permitted bending radius, stationary application/permanent installation
- 456 mm
- Weight
- 4,001.9 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247943 Cut length Ring, Drum NYCWY 3X120 SM/70 3 120 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 120 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 70 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 40 mm
- Min. permitted bending radius, stationary application/permanent installation
- 480 mm
- Weight
- 4,846.1 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248810 Cut length Ring, Drum NYCWY 3X150 SM/70 3 150 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 150 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 70 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 44 mm
- Min. permitted bending radius, stationary application/permanent installation
- 528 mm
- Weight
- 5,865.7 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248889 Cut length Ring, Drum NYCWY 3X185 SM/95 3 185 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 185 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 95 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 49 mm
- Min. permitted bending radius, stationary application/permanent installation
- 588 mm
- Weight
- 7,490.5 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247998 Cut length Ring, Drum NYCWY 3X240 SM/120 3 240 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 240 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 120 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 52 mm
- Min. permitted bending radius, stationary application/permanent installation
- 624 mm
- Weight
- 9,353.2 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248018 Cut length Ring, Drum NYCWY 4X10 RE/10 4 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 20 mm
- Min. permitted bending radius, stationary application/permanent installation
- 240 mm
- Weight
- 812.38 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248032 Cut length Ring, Drum 248056 500 m 500 Drum NYCWY 4X16 RE/16 4 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 23 mm
- Min. permitted bending radius, stationary application/permanent installation
- 276 mm
- Weight
- 1,144.7 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248070 Cut length Ring, Drum 248094 500 m 500 Drum NYCWY 4X25 RM/16 4 25 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 25 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 27 mm
- Min. permitted bending radius, stationary application/permanent installation
- 324 mm
- Weight
- 1,672.7 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248117 Cut length Ring, Drum 248131 500 m 500 Drum NYCWY 4X35 RM/16 4 35 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 35 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 30 mm
- Weight
- 2,119.3 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 358304 Cut length Ring, Drum 732784 500 m 500 Drum NYCWY 4X50 SM/25 4 50 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 50 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 25 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 32 mm
- Min. permitted bending radius, stationary application/permanent installation
- 384 mm
- Weight
- 2,646.3 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248230 Cut length Ring, Drum 248278 500 m 500 Drum NYCWY 4X70 SM/35 4 70 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 70 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 35 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 34 mm
- Min. permitted bending radius, stationary application/permanent installation
- 408 mm
- Weight
- 3,515.8 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248537 Cut length Ring, Drum NYCWY 4X95 SM/50 4 95 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 95 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 50 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 40 mm
- Min. permitted bending radius, stationary application/permanent installation
- 480 mm
- Weight
- 4,933 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248599 Cut length Ring, Drum 671021 500 m 500 Drum NYCWY 4X120 SM/70 4 120 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 120 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 70 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 45 mm
- Min. permitted bending radius, stationary application/permanent installation
- 540 mm
- Weight
- 6,241.9 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248674 Cut length Ring, Drum 670963 500 m 500 Drum NYCWY 4X150 SM/70 4 150 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 150 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 70 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 47 mm
- Min. permitted bending radius, stationary application/permanent installation
- 564 mm
- Weight
- 7,342.1 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248711 Cut length Ring, Drum 670970 500 m 500 Drum NYCWY 4X185 SM/95 4 185 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 185 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 95 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 54 mm
- Min. permitted bending radius, stationary application/permanent installation
- 648 mm
- Weight
- 9,382.3 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248766 Cut length Ring, Drum 670987 500 m 500 Drum NYCWY 4X240 SM/120 4 240 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 240 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 120 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Cable geometry
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 59 mm
- Min. permitted bending radius, stationary application/permanent installation
- 708 mm
- Weight
- 11,919 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- Suitable as installation cable
- Certified for shipboard application
- Suitable as medium-voltage cable
- Suitable as high-voltage cable
- Certified as airport lighting cable
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248797 Cut length Ring, Drum 670994 500 m 500 Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "NYCWY"