NYCWY
According to VDE 0276 part 603.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product NYCWY 2X10 RE/10 2 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 18 mm
- Min. permitted bending radius, stationary application/permanent installation
- 216 mm
- Weight
- 588.75 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 239405 Cut length Ring, Drum NYCWY 2X16 RE/16 2 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 20 mm
- Min. permitted bending radius, stationary application/permanent installation
- 240 mm
- Weight
- 813.89 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 249237 Cut length Ring, Drum NYCWY 3X10 RE/10 3 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 19 mm
- Min. permitted bending radius, stationary application/permanent installation
- 228 mm
- Weight
- 685.71 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247615 Cut length Ring, Drum 247639 500 m 500 Drum NYCWY 3X16 RE/16 3 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 21 mm
- Min. permitted bending radius, stationary application/permanent installation
- 252 mm
- Weight
- 960.26 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247653 Cut length Ring, Drum 247677 500 m 500 Drum NYCWY 3X25 RM/16 3 25 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 25 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 25 mm
- Min. permitted bending radius, stationary application/permanent installation
- 300 mm
- Weight
- 1,380.5 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247691 Cut length Ring, Drum NYCWY 3X35 RM/16 3 35 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 35 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 28 mm
- Weight
- 1,732.9 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 358342 Cut length Ring, Drum NYCWY 3X50 SM/25 3 50 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 50 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 25 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 28 mm
- Min. permitted bending radius, stationary application/permanent installation
- 336 mm
- Weight
- 2,030.9 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247806 Cut length Ring, Drum NYCWY 3X70 SM/35 3 70 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 70 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 35 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 31 mm
- Min. permitted bending radius, stationary application/permanent installation
- 372 mm
- Weight
- 2,794.2 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247875 Cut length Ring, Drum NYCWY 3X95 SM/50 3 95 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 95 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 50 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 38 mm
- Min. permitted bending radius, stationary application/permanent installation
- 456 mm
- Weight
- 4,001.9 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247943 Cut length Ring, Drum NYCWY 3X120 SM/70 3 120 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 120 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 70 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 40 mm
- Min. permitted bending radius, stationary application/permanent installation
- 480 mm
- Weight
- 4,846.1 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248810 Cut length Ring, Drum NYCWY 3X150 SM/70 3 150 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 150 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 70 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 44 mm
- Min. permitted bending radius, stationary application/permanent installation
- 528 mm
- Weight
- 5,865.7 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248889 Cut length Ring, Drum NYCWY 3X185 SM/95 3 185 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 185 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 95 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 49 mm
- Min. permitted bending radius, stationary application/permanent installation
- 588 mm
- Weight
- 7,490.5 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 247998 Cut length Ring, Drum NYCWY 3X240 SM/120 3 240 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 240 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 120 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 52 mm
- Min. permitted bending radius, stationary application/permanent installation
- 624 mm
- Weight
- 9,353.2 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248018 Cut length Ring, Drum NYCWY 4X10 RE/10 4 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 20 mm
- Min. permitted bending radius, stationary application/permanent installation
- 240 mm
- Weight
- 812.38 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248032 Cut length Ring, Drum 248056 500 m 500 Drum NYCWY 4X16 RE/16 4 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 23 mm
- Min. permitted bending radius, stationary application/permanent installation
- 276 mm
- Weight
- 1,144.7 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248070 Cut length Ring, Drum 248094 500 m 500 Drum NYCWY 4X25 RM/16 4 25 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 25 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 27 mm
- Min. permitted bending radius, stationary application/permanent installation
- 324 mm
- Weight
- 1,672.7 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248117 Cut length Ring, Drum 248131 500 m 500 Drum NYCWY 4X35 RM/16 4 35 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 35 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 30 mm
- Weight
- 2,119.3 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 358304 Cut length Ring, Drum 732784 500 m 500 Drum NYCWY 4X50 SM/25 4 50 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 50 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 25 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 32 mm
- Min. permitted bending radius, stationary application/permanent installation
- 384 mm
- Weight
- 2,646.3 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248230 Cut length Ring, Drum 248278 500 m 500 Drum NYCWY 4X70 SM/35 4 70 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 70 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 35 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 34 mm
- Min. permitted bending radius, stationary application/permanent installation
- 408 mm
- Weight
- 3,515.8 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248537 Cut length Ring, Drum NYCWY 4X95 SM/50 4 95 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 95 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 50 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 40 mm
- Min. permitted bending radius, stationary application/permanent installation
- 480 mm
- Weight
- 4,933 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248599 Cut length Ring, Drum 671021 500 m 500 Drum NYCWY 4X120 SM/70 4 120 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 120 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 70 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 45 mm
- Min. permitted bending radius, stationary application/permanent installation
- 540 mm
- Weight
- 6,241.9 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248674 Cut length Ring, Drum 670963 500 m 500 Drum NYCWY 4X150 SM/70 4 150 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 150 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 70 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 47 mm
- Min. permitted bending radius, stationary application/permanent installation
- 564 mm
- Weight
- 7,342.1 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248711 Cut length Ring, Drum 670970 500 m 500 Drum NYCWY 4X185 SM/95 4 185 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 185 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 95 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 54 mm
- Min. permitted bending radius, stationary application/permanent installation
- 648 mm
- Weight
- 9,382.3 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248766 Cut length Ring, Drum 670987 500 m 500 Drum NYCWY 4X240 SM/120 4 240 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 240 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Copper
- Nominal cross section concentric conductor
- 120 mm²
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Black
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Eca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 59 mm
- Min. permitted bending radius, stationary application/permanent installation
- 708 mm
- Weight
- 11,919 kg/km
- Max. conductor temperature
- 70 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 160 °C
- Insulation
- PVC
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 248797 Cut length Ring, Drum 670994 500 m 500 Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "NYCWY"
If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.