VG-YMvKas Dca
based upon HD 604 4D.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product VG-YMvKas Dca Dca 2X4 RE/4 2 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 4 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 16 mm
- Min. permitted bending radius, stationary application/permanent installation
- 192 mm
- Weight
- 444.13 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 282814 Cut length Ring, Drum VG-YMvKas Dca Dca 3X10 RM/10 3 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 20 mm
- Min. permitted bending radius, stationary application/permanent installation
- 228 mm
- Weight
- 791.38 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 263387 Cut length Ring, Drum VG-YMvKas Dca Dca 3X10 RE/10 (EVU) 3 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 19 mm
- Weight
- 766.8 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 496426 Cut length Ring, Drum VG-YMvKas Dca Dca 3X16 RM/16 3 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 22 mm
- Min. permitted bending radius, stationary application/permanent installation
- 252 mm
- Weight
- 1,059.7 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 263486 Cut length Ring, Drum VG-YMvKas Dca Dca 3X25 RM/16 3 25 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 25 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 25 mm
- Weight
- 1,435.6 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 548927 Cut length Ring, Drum VG-YMvKas Dca Dca 3X35 SM/16 3 35 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 35 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 25 mm
- Weight
- 1,599.1 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 742981 Cut length Ring, Drum VG-YMvKas Dca Dca 3X185 SM/95 3 185 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 185 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 95 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 48 mm
- Weight
- 7,386 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 743797 Cut length Ring, Drum VG-YMvKas Dca Dca 4X10 RM/10 4 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 10 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Cable geometry
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 21 mm
- Min. permitted bending radius, stationary application/permanent installation
- 252 mm
- Weight
- 936.4 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- Suitable as installation cable
- Certified for shipboard application
- Suitable as medium-voltage cable
- Suitable as high-voltage cable
- Certified as airport lighting cable
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 263431 Cut length Ring, Drum 822461 100 m 100 Drum 805990 500 m 500 Drum VG-YMvKas Dca Dca 4X16 RM/16 4 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 23 mm
- Min. permitted bending radius, stationary application/permanent installation
- 276 mm
- Weight
- 1,265.2 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 263530 Cut length Ring, Drum 806027 500 m 500 Drum VG-YMvKas Dca Dca 4X16 RM/16 (EVU) 4 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 25 mm
- Weight
- 1,339.9 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 459834 Cut length Ring, Drum VG-YMvKas Dca Dca 4X25 RM/16 4 25 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 25 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 28 mm
- Weight
- 1,774.5 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 547395 Cut length Ring, Drum 806034 500 m 500 Drum VG-YMvKas Dca Dca 4X35 SM/16 4 35 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 35 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 16 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 28 mm
- Weight
- 2,074.9 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 570867 Cut length Ring, Drum 806041 500 m 500 Drum VG-YMvKas Dca Dca 4X50 SM/25 4 50 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 50 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 25 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 33 mm
- Weight
- 2,796.8 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 509911 Cut length Ring, Drum 806058 500 m 500 Drum VG-YMvKas Dca Dca 4X70 SM/35 4 70 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 70 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 35 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 36 mm
- Weight
- 3,664.9 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 554652 Cut length Ring, Drum VG-YMvKas Dca Dca 4X95 SM/50 4 95 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 95 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 50 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 40 mm
- Weight
- 4,830.6 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 554713 Cut length Ring, Drum VG-YMvKas Dca Dca 4X120 SM/60 4 120 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 120 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 60 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 45 mm
- Weight
- 6,062.9 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 554782 Cut length Ring, Drum VG-YMvKas Dca Dca 4X150 SM/75 4 150 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 150 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 75 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 47 mm
- Weight
- 7,200.8 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 554850 Cut length Ring, Drum VG-YMvKas Dca Dca 4X185 SM/95 4 185 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 185 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 95 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Cable geometry
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 55 mm
- Weight
- 9,604.3 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- Suitable as installation cable
- Certified for shipboard application
- Suitable as medium-voltage cable
- Suitable as high-voltage cable
- Certified as airport lighting cable
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 554911 Cut length Ring, Drum VG-YMvKas Dca Dca 4X240SM/120 4 240 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 240 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Sector-shaped
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 120 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 60 mm
- Weight
- 12,090 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 505548 Cut length Ring, Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "VG-YMvKas Dca"
If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.