VO-YMvKas Dca
according HD 604 part 4D.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product VO-YMvKas Dca Dca 2X1,5 RE/1,5 2 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 1.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- Yes
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 14 mm
- Min. permitted bending radius, stationary application/permanent installation
- 168 mm
- Weight
- 250.53 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 262816 Cut length Ring, Drum 766758 100 m 2,000 Ring 310920 500 m 2,000 Drum VO-YMvKas Dca Dca 2X2,5 RE/2,5 2 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 2.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 14 mm
- Min. permitted bending radius, stationary application/permanent installation
- 168 mm
- Weight
- 284.89 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 263011 Cut length Ring, Drum 681891 10 m 1,020 Ring 299034 25 m 1,350 Ring 299041 50 m 2,400 Ring 706792 50 m 2,400 Ring 299058 100 m 2,000 Ring 299072 500 m 2,000 Drum VO-YMvKas Dca Dca 2X4RE/4 2 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 4 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 16 mm
- Weight
- 357.06 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 615377 Cut length Ring, Drum 766826 100 m 1,400 Ring 766833 500 m 2,000 Drum VO-YMvKas Dca Dca 2X6RE/6 2 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 17 mm
- Weight
- 434.66 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
- Paletteinheit
- 1,200 m
- Bruttogewicht pro Paletteinheit
- 544.39 kg
Product No. Individual length Pallet unit Packing 766840 100 m 1,200 Ring 766864 500 m 2,000 Drum VO-YMvKas Dca Dca 3X1,5 RE/1,5 3 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 1.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- Yes
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 14 mm
- Min. permitted bending radius, stationary application/permanent installation
- 168 mm
- Weight
- 264.61 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 262861 Cut length Ring, Drum 766765 100 m 1,800 Ring 766772 500 m 2,000 Drum VO-YMvKas Dca Dca 3X2,5 RE/2,5 3 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 2.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 15 mm
- Min. permitted bending radius, stationary application/permanent installation
- 180 mm
- Weight
- 311.68 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 263066 Cut length Ring, Drum 277889 50 m 1,200 Ring 706846 50 m 1,200 Ring 277896 100 m 1,600 Ring 299126 500 m 2,000 Drum VO-YMvKas Dca Dca 3X2,5 RE/2,5 (EVU) 3 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 2.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- Yes
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 15 mm
- Weight
- 319.46 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 496464 Cut length Ring, Drum 496525 Cut length Ring, Drum 496518 100 m 1,600 Ring VO-YMvKas Dca Dca 3X4RE/4 3 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 4 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 17 mm
- Weight
- 396.61 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 615322 Cut length Ring, Drum VO-YMvKas Dca Dca 3X6RE/6 3 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 6 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 17 mm
- Weight
- 494.15 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 615919 Cut length Ring, Drum 807970 Cut length Ring, Drum VO-YMvKas Dca Dca 3X6RE/6 EVU 3 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 6 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- Yes
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 20 mm
- Weight
- 522.97 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 656806 Cut length Ring, Drum VO-YMvKas Dca Dca 4X1,5 RE/1,5 4 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 1.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- Yes
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 15 mm
- Min. permitted bending radius, stationary application/permanent installation
- 180 mm
- Weight
- 291.66 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 262915 Cut length Ring, Drum 766789 100 m 1,600 Ring 766796 500 m 2,000 Drum VO-YMvKas Dca Dca 4X2,5 RE/2,5 4 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 2.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- Yes
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 16 mm
- Min. permitted bending radius, stationary application/permanent installation
- 192 mm
- Weight
- 362.79 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 263110 Cut length Ring, Drum 277902 50 m 1,200 Ring 277919 100 m 1,400 Ring VO-YMvKas Dca Dca 4X4RE/4 4 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 4 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 17 mm
- Weight
- 454.25 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 615278 Cut length Ring, Drum 766871 100 m 1,200 Ring 766888 500 m 2,000 Drum VO-YMvKas Dca Dca 4X6RE/6 4 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification according to HD 308 S2
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 6 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Cable geometry
- Conductive coating
- No
- Longitudinal water blocking conductors
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 18 mm
- Weight
- 565.09 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- Suitable as installation cable
- Certified for shipboard application
- Suitable as medium-voltage cable
- Suitable as high-voltage cable
- Certified as airport lighting cable
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 615438 Cut length Ring, Drum 766901 Cut length Ring, Drum 766895 100 m 1,000 Ring VO-YMvKas Dca Dca 4X6RE/6 EVU 4 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 6 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- Yes
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 18 mm
- Weight
- 576.08 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 656035 Cut length Ring, Drum 792405 Cut length Ring, Drum VO-YMvKas Dca Dca 4X6RE+1X2,5RE/6 EVU 4 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 6 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 22 mm
- Weight
- 650.41 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 656851 Cut length Ring, Drum VO-YMvKas Dca Dca 5X1,5 RE/1,5 5 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 5 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 1.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 15 mm
- Min. permitted bending radius, stationary application/permanent installation
- 180 mm
- Weight
- 323.01 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 262960 Cut length Ring, Drum 766802 100 m 1,600 Ring 766819 500 m 2,000 Drum VO-YMvKas Dca Dca 5X2,5 RE/2,5 5 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 5 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- Other
- Nominal cross section concentric conductor
- 2.5 mm²
- Armouring
- Yes
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 16 mm
- Min. permitted bending radius, stationary application/permanent installation
- 192 mm
- Weight
- 392 kg/km
- Max. conductor temperature
- 90 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 263172 Cut length Ring, Drum 277933 100 m 1,400 Ring 299140 500 m 500 Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "VO-YMvKas Dca"
If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.