YMvK Dca
according HD 604 4D.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product YMvK Dca Dca 2X1,5 RE 2 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 10 mm
- Min. permitted bending radius, stationary application/permanent installation
- 100 mm
- Weight
- 131.36 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
- Paletteinheit
- 4,200 m
- Bruttogewicht pro Paletteinheit
- 574.51 kg
Product No. Individual length Pallet unit Packing 282364 100 m 4,200 Ring 262144 500 m 5,000 Drum YMvK Dca Dca 2X2,5 RE 2 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 11 mm
- Min. permitted bending radius, stationary application/permanent installation
- 110 mm
- Weight
- 162.54 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
- Paletteinheit
- 3,600 m
- Außendurchmesser
- 390 mm
- Kerndurchmesser
- 200 mm
- Höhe
- 122 mm
- Bruttogewicht pro Paletteinheit
- 607.94 kg
Product No. Individual length Pallet unit Packing 282371 100 m 3,600 Ring 262175 500 m 2,000 Drum YMvK Dca Dca 2x4 RE 2 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 12 mm
- Weight
- 206.94 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 595136 Cut length Ring, Drum YMvK Dca Dca 2X6 RE 2 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 13 mm
- Weight
- 261.54 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 595167 Cut length Ring, Drum YMvK Dca Dca 2X10 RM 2 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 15 mm
- Weight
- 385.74 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 595259 Cut length Ring, Drum YMvK Dca Dca 2X16 RM 2 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 2 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 17 mm
- Weight
- 540.16 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 595280 Cut length Ring, Drum YMvK Dca Dca 3G1,5 RE 3 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 10 mm
- Min. permitted bending radius, stationary application/permanent installation
- 100 mm
- Weight
- 148.2 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 326600 Cut length Ring, Drum 815852 25 m 2,250 Ring 262205 100 m 4,200 Ring 282036 500 m 5,000 Drum YMvK Dca Dca 3G2,5 RE 3 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 11 mm
- Weight
- 187.55 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 333714 Cut length Ring, Drum 639182 50 m 3,300 Ring 262236 100 m 3,000 Ring 282043 500 m 2,000 Drum 547500 1000 m 4,000 Drum YMvK Dca Dca 3G4 RE 3 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 12 mm
- Weight
- 244.33 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 441006 Cut length Ring, Drum 440962 100 m 3,000 Ring 440993 500 m 2,000 Drum YMvK Dca Dca 3G6 RE 3 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 13 mm
- Weight
- 315.1 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 594757 Cut length Ring, Drum 685929 100 m 1,600 Ring 766741 500 m 2,000 Drum YMvK Dca Dca 3G10 RM 3 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 16 mm
- Weight
- 472.66 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 594788 Cut length Ring, Drum YMvK Dca Dca 3G16 RM 3 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 18 mm
- Weight
- 675.02 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 594832 Cut length Ring, Drum YMvK Dca Dca 4G1,5 RE 4 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 11 mm
- Min. permitted bending radius, stationary application/permanent installation
- 110 mm
- Weight
- 172.3 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
- Paletteinheit
- 3,000 m
- Außendurchmesser
- 390 mm
- Kerndurchmesser
- 200 mm
- Höhe
- 130 mm
- Bruttogewicht pro Paletteinheit
- 537.45 kg
Product No. Individual length Pallet unit Packing 262267 100 m 3,000 Ring 282050 500 m 2,000 Drum YMvK Dca Dca 4G2,5 RE 4 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 12 mm
- Min. permitted bending radius, stationary application/permanent installation
- 120 mm
- Weight
- 221.78 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 262298 Cut length Ring, Drum 766710 100 m 2,400 Ring 310913 500 m 2,000 Drum YMvK Dca Dca 4G2,5 RE (GG/SW/BL/BR 4 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 12 mm
- Weight
- 221.78 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 581771 Cut length Ring, Drum YMvK Dca Dca 4G4 RE 4 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 13 mm
- Min. permitted bending radius, stationary application/permanent installation
- 130 mm
- Weight
- 293.59 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 262328 Cut length Ring, Drum 277940 50 m 2,400 Ring 277957 100 m 2,000 Ring 766727 500 m 2,000 Drum YMvK Dca Dca 4G4 RE (GG/SW/BL/BR) 4 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 13 mm
- Min. permitted bending radius, stationary application/permanent installation
- 156 mm
- Weight
- 293.57 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
- Paletteinheit
- 2,000 m
- Bruttogewicht pro Paletteinheit
- 609.94 kg
Product No. Individual length Pallet unit Packing 777709 100 m 2,000 Ring 197378 500 m 2,000 Drum YMvK Dca Dca 4G6 RE (GG/SW/BL/BR) 4 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 14 mm
- Min. permitted bending radius, stationary application/permanent installation
- 168 mm
- Weight
- 383.38 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 197385 Cut length Ring, Drum YMvK Dca Dca 4G6 RE 4 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 14 mm
- Min. permitted bending radius, stationary application/permanent installation
- 140 mm
- Weight
- 383.38 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 262359 Cut length Ring, Drum 277964 50 m 1,200 Ring 277971 100 m 1,600 Ring YMvK Dca Dca 4X6 RE 4 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 14 mm
- Weight
- 383.38 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
- Paletteinheit
- 2,000 m
- Außendurchmesser
- 752 mm
- Kerndurchmesser
- 315 mm
- Höhe
- 419 mm
- Bruttogewicht pro Paletteinheit
- 840.2 kg
Product No. Individual length Pallet unit Packing 662876 500 m 2,000 Drum YMvK Dca Dca 4G10 RM 4 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 17 mm
- Weight
- 582.03 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 512607 Cut length Ring, Drum 807901 Cut length Ring, Drum YMvK Dca Dca 4G10 RM (GG/SW/BL/BR) 4 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 17 mm
- Weight
- 583.18 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 661534 Cut length Ring, Drum YMvK Dca Dca 4G16 RM (GG/SW/BL/BR) 4 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 19 mm
- Min. permitted bending radius, stationary application/permanent installation
- 228 mm
- Weight
- 840.73 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 12 x Außen-Ø
Product No. Individual length Pallet unit Packing 197408 Cut length Ring, Drum YMvK Dca Dca 4G16 RM 4 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 4 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 19 mm
- Min. permitted bending radius, stationary application/permanent installation
- 190 mm
- Weight
- 840.73 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 262427 Cut length Ring, Drum 278008 50 m 900 Ring YMvK Dca Dca 5G1,5 RE 5 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 5 Stck
- Core identification according to HD 308 S2
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Cable geometry
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 12 mm
- Min. permitted bending radius, stationary application/permanent installation
- 120 mm
- Weight
- 199.7 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- Suitable as installation cable
- Certified for shipboard application
- Suitable as medium-voltage cable
- Suitable as high-voltage cable
- Certified as airport lighting cable
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
- Paletteinheit
- 3,000 m
- Außendurchmesser
- 390 mm
- Kerndurchmesser
- 200 mm
- Höhe
- 149 mm
- Bruttogewicht pro Paletteinheit
- 621.9 kg
Product No. Individual length Pallet unit Packing 262502 100 m 3,000 Ring 310814 500 m 2,000 Drum YMvK Dca Dca 5G2,5 RE 5 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 5 Stck
- Core identification according to HD 308 S2
- Yes
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 13 mm
- Min. permitted bending radius, stationary application/permanent installation
- 130 mm
- Weight
- 255.5 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 262533 Cut length Ring, Drum 779901 50 m 3,000 Ring 639205 100 m 2,400 Ring 639212 500 m 2,000 Drum YMvK Dca Dca 5G4 RE 5 4 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 4 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 5 Stck
- Core identification according to HD 308 S2
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Cable geometry
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 14 mm
- Min. permitted bending radius, stationary application/permanent installation
- 140 mm
- Weight
- 347.66 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- Suitable as installation cable
- Certified for shipboard application
- Suitable as medium-voltage cable
- Suitable as high-voltage cable
- Certified as airport lighting cable
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 262564 Cut length Ring, Drum 278015 50 m 1,200 Ring 278022 100 m 1,600 Ring 310869 500 m 2,000 Drum YMvK Dca Dca 5G6 RE 5 6 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 6 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 5 Stck
- Core identification according to HD 308 S2
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Cable geometry
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 15 mm
- Min. permitted bending radius, stationary application/permanent installation
- 150 mm
- Weight
- 456.94 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- Suitable as installation cable
- Certified for shipboard application
- Suitable as medium-voltage cable
- Suitable as high-voltage cable
- Certified as airport lighting cable
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 262595 Cut length Ring, Drum 278039 50 m 1,000 Ring 278046 100 m 1,400 Ring 766734 500 m 2,000 Drum YMvK Dca Dca 5G10 RM 5 10 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 10 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 5 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 18 mm
- Weight
- 700.29 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 511051 Cut length Ring, Drum 807888 Cut length Ring, Drum 822454 100 m 400 Drum 806072 500 m 500 Drum YMvK Dca Dca 5G16 RM 5 16 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 16 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 5 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 21 mm
- Min. permitted bending radius, stationary application/permanent installation
- 210 mm
- Weight
- 1,020 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 262663 Cut length Ring, Drum 806065 500 m 500 Drum YMvK Dca Dca 7G1,5 RE 7 1.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 1.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 7 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 13 mm
- Min. permitted bending radius, stationary application/permanent installation
- 130 mm
- Weight
- 237.72 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 251452 Cut length Ring, Drum 310685 500 m 2,000 Drum YMvK Dca Dca 7G2,5 RE 7 2.5 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 2.5 mm²
- Conductor category
- Class 1 = solid
- Shape of conductor
- Round
- Number of cores
- 7 Stck
- Core identification
- Colour
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- Yes
- Inner semi-conducting layer
- No
- Outer semi-conducting layer
- No
- Screen
- No
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Grey
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s2
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a3
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-3-24
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 14 mm
- Min. permitted bending radius, stationary application/permanent installation
- 140 mm
- Weight
- 315.48 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Permitted cable outer temperature after assembling without vibration
- -30 <=> 70 °C
- Nominal voltage U0
- 0.6 kV
- Nominal voltage U
- 1 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 10 x Außen-Ø
Product No. Individual length Pallet unit Packing 251483 Cut length Ring, Drum 310876 500 m 2,000 Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "YMvK Dca"