NA2XSY 20kV
According to VDE 0276 part 620.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product NA2XSY 20kV 1X50 RM/16 20kV 1 50 mm² - Conductor material
- Aluminium
- Conductor surface
- Bare
- Nominal cross section conductor
- 50 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 30 mm
- Min. permitted bending radius, stationary application/permanent installation
- 450 mm
- Weight
- 867.68 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 234875 Cut length Ring, Drum NA2XSY 20kV 1X70 RM/16 20kV 1 70 mm² - Conductor material
- Aluminium
- Conductor surface
- Bare
- Nominal cross section conductor
- 70 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 32 mm
- Min. permitted bending radius, stationary application/permanent installation
- 480 mm
- Weight
- 969.51 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 234905 Cut length Ring, Drum NA2XSY 20kV 1X95 RM/16 20kV 1 95 mm² - Conductor material
- Aluminium
- Conductor surface
- Bare
- Nominal cross section conductor
- 95 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 34 mm
- Min. permitted bending radius, stationary application/permanent installation
- 510 mm
- Weight
- 1,098.6 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 234936 Cut length Ring, Drum NA2XSY 20kV 1X120 RM/16 20kV 1 120 mm² - Conductor material
- Aluminium
- Conductor surface
- Bare
- Nominal cross section conductor
- 120 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 35 mm
- Min. permitted bending radius, stationary application/permanent installation
- 525 mm
- Weight
- 1,209.5 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 234967 Cut length Ring, Drum NA2XSY 20kV 1X150 RM/25 20kV 1 150 mm² - Conductor material
- Aluminium
- Conductor surface
- Bare
- Nominal cross section conductor
- 150 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 36 mm
- Min. permitted bending radius, stationary application/permanent installation
- 540 mm
- Weight
- 1,398 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 234998 Cut length Ring, Drum NA2XSY 20kV 1X185 RM/25 20kV 1 185 mm² - Conductor material
- Aluminium
- Conductor surface
- Bare
- Nominal cross section conductor
- 185 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 38 mm
- Min. permitted bending radius, stationary application/permanent installation
- 570 mm
- Weight
- 1,551.2 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 235025 Cut length Ring, Drum NA2XSY 20kV 1X240 RM/25 20kV 1 240 mm² - Conductor material
- Aluminium
- Conductor surface
- Bare
- Nominal cross section conductor
- 240 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 41 mm
- Min. permitted bending radius, stationary application/permanent installation
- 615 mm
- Weight
- 1,770.1 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 235056 Cut length Ring, Drum NA2XSY 20kV 1X400 RM/35 20kV 1 300 mm² - Conductor material
- Aluminium
- Conductor surface
- Bare
- Nominal cross section conductor
- 300 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 1 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Protective conductor
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Screen
- Yes
- Concentric conductor
- None
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Reaction-to-fire according to EN 13501-6: Class
- Fca
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 46 mm
- Min. permitted bending radius, stationary application/permanent installation
- 690 mm
- Weight
- 2,414.8 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- -5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 295227 Cut length Ring, Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "NA2XSY 20kV"
If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.