N2XSY (3x) 20kV
according VDE 0276 part 620.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product N2XSY (3x) 20kV 3X1X50 RM/16 20kV 3 50 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 50 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 65 mm
- Weight
- 3,466.5 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 459797 Cut length Ring, Drum N2XSY (3x) 20kV 3X1X240 RM/25 20kV 3 240 mm² - Conductor material
- Copper
- Conductor surface
- Bare
- Nominal cross section conductor
- 240 mm²
- Conductor category
- Class 2 = stranded
- Shape of conductor
- Round
- Number of cores
- 3 Stck
- Core identification
- None
- Laminated sheath
- No
- Fibre optic elements
- No
- Inner semi-conducting layer
- Yes
- Outer semi-conducting layer
- Yes
- Armouring
- No
- Material outer sheath
- Polyvinyl chloride (PVC)
- Specification material outer sheath
- Other
- Colour outer sheath
- Red
- Conductive coating
- No
- Longitudinal water blocking conductors
- No
- Longitudinal water blocking screen
- No
- Halogen free (acc. EN 60754-1/2)
- No
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- No
- Outer diameter approx.
- 88 mm
- Weight
- 9,704.1 kg/km
- Max. conductor temperature
- 90 °C
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 12 kV
- Nominal voltage U
- 20 kV
- max. short circuit temperature
- 250 °C
- Insulation
- XLPE (VPE)
- Minimum bending radius
- 15 x Außen-Ø
Product No. Individual length Pallet unit Packing 540464 Cut length Ring, Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "N2XSY (3x) 20kV"
If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.